(a) Full cutoff requirement.

(1) Commercial and industrial lighting zones. Except for uplighting applications permitted within this Chapter, any luminaire used for outdoor lighting in a commercial or industrial lighting zone shall be a full cutoff luminaire and shall be installed in the proper orientation to achieve full cutoff performance with respect to a horizontal plane.

(2) Street lighting. Any luminaire used for street lighting shall be a full cutoff one hundred (100) watt high pressure sodium (HPS) luminaire and shall be installed in the proper orientation to achieve full cutoff performance with respect to a horizontal plane at intersections only. The luminaire, as well as any poles, brackets, supports, and mounting hardware shall comply with current town standards set forth in the Town design standard manual.

(b) Installed height. The installed height of any luminaire used for outdoor lighting on any zoning lot, except for street lighting, shall not exceed twenty-five (25) feet, including the luminaire.

(Ord. No. 1569, § 1, 2-28-13)